PA12 UBE 3014U

PA12 UBE 3014U Resin

Material Introduction: PA12 UBE 3014U is a flame‑retardant reinforced polyamide‑12 resin specially developed for ultra‑thin‑wall electronic components. It features ultra‑high flowability, halogen‑free eco‑friendly system, and achieves UL94 V‑0 rating at 0.25 mm thin‑wall thickness.

Main Applications

Micro‑electronic connectors (core application): USB4 Type‑C housing, 5G millimeter‑wave antenna radome (0.25 mm V‑0 & 10 Gbps signal integrity requirement).

New‑energy‑vehicle high‑voltage components: BMS insulation separators, on‑board charger sockets (CTI 600 V, arc‑resistance>120 s).

Smart‑wear structural parts: TWS ear‑bud charging‑case hinges, smart‑watch heart‑rate‑sensor supports (0.3 mm wall thickness, 5000‑cycle opening‑closing lifetime).

Industrial‑automation precision parts: Servo‑motor encoder housings, robot PCB fixing brackets (lubricant‑resistant & anti‑EMI).

Medical‑electronic housings: Portable ultrasound‑probe shells, insulin‑pump circuit compartments (ISO 10993‑5 biocompatibility passed).

Performance Parameters

Performance Category Test Item Test Standard Unit Typical Value Remarks & Interpretation
Basic Physical Properties Density ISO 1183 g/cm³ 1.24‑1.26 Flame‑retardant reinforced PA12
  Water Absorption (23℃/24h) ISO 62 % 0.2‑0.3 Low‑moisture‑absorption grade
Mechanical Properties Tensile Strength ISO 527 MPa 75‑80
  Flexural Modulus ISO 178 MPa 3800‑4000
  Notched Charpy Impact Strength (23℃) ISO 179/1eA kJ/m² 6‑8
Flammability & Electrical Properties UL94 Rating UL 94 V‑0 (0.25 mm) Halogen‑free flame retardant
  Glow‑Wire Ignition Temperature IEC 60695‑2‑12 875
  Comparative Tracking Index (CTI) IEC 60112 V 600
  Dielectric Constant (1 GHz) IEC 60250 3.0 Good high‑frequency signal performance
Thermal Properties Heat‑Distortion Temperature (1.8 MPa) ISO 75 155‑160
  Coefficient of Linear Thermal Expansion ISO 11359 /℃ 2.5×10⁻⁵

Processing Parameters

Processing Step Parameter Range Key Control Points
Drying 85 ℃ × 4 h vacuum drying Moisture content ≤0.015%. Sensitive to flame‑retardant hydrolysis.
Barrel Temperature Rear zone:190‑200 ℃ >220 ℃ triggers flame‑retardant decomposition & HBr release.
  Middle zone:205‑215 ℃
  Front zone / Nozzle:215‑225 ℃ Actual melt temperature ≤230 ℃.
Mold Temperature 90‑110 ℃ Mold temperature<80 ℃ causes flame‑retardant migration and surface chalking.
Injection Speed Ultra‑high speed (≥95% of maximum rate) Low‑speed flow leads to uneven flame‑retardant distribution.
Holding Pressure 30‑50% of injection pressure High pressure induces internal‑stress cracking especially at sharp corners.
Screw Design Dual‑alloy barrier‑type Compression ratio 2.0‑2.2, L/D ≥22.
Hot‑runner System Valve‑gate type is mandatory Avoid flame‑retardant thermal residence; residence time<90 s.