PP Formosa Plastics 3003
PP Formosa Plastics 3003 Resin
Material Introduction: PP Formosa Plastics 3003 is pipe‑grade polypropylene featured with excellent low‑temperature resistance and high‑impact performance, mainly used for cold‑water piping systems.
Main Applications
PPB cold‑water pipes: core application for indoor building cold‑water transmission systems.
Thermoforming sheets: for vacuum‑formed sheet products.
Blow‑molded articles: certain hollow molded products.
Performance Parameters
| Performance Category | Test Item | Test Condition | Test Standard | Typical Value | Unit | Remarks & Interpretation |
|---|---|---|---|---|---|---|
| Basic Properties | Density | ‑ | ISO 1183 | 0.90 | g/cm³ | Typical PP density. |
| Melt Flow Rate (MFR) | 230℃/2.16kg | ISO 1133 | 0.35 | g/10 min | Low‑flow grade for pipe extrusion. | |
| Molding Shrinkage | ‑ | Internal Method | 1.3‑1.7 | % | Reference for mold dimensional compensation. | |
| Mechanical Properties | Tensile Yield Strength | Yield point | ISO 527‑2 | 24.5 | MPa | Tensile yield performance. |
| Elongation at Break | Break point | ISO 527‑2 | ≥500 | % | Good ductility. | |
| Flexural Modulus | ‑ | ISO 178 | 1230 | MPa | High rigidity characteristic. | |
| Rockwell Hardness | R scale | ISO 2039‑2 | 95 | ‑ | Surface hardness. | |
| Izod Notched Impact Strength | 23℃ | ISO 180 | 780 | J/m | Excellent room‑temperature impact resistance. | |
| Izod Notched Impact Strength | -20℃ | ISO 180 | 16 | J/m | Low‑temperature notch impact property. | |
| Thermal Properties | Heat‑Distortion Temperature(HDT) | 1.8 MPa, non‑annealed | ISO 75‑2/A | 105 | °C | Heat‑resistance reference index. |
| Vicat Softening Temperature | ‑ | ISO 306 | 150 | ℃ | Vicat softening point. |
Injection‑Molding Process Parameters
‑Melting temperature:200‑270℃ ‑Mold temperature:40‑80℃. Higher mold temperature improves surface gloss and dimensional stability. ‑Injection pressure:700‑1000 bar, adjust according to product structure and wall‑thickness. ‑Injection speed:medium‑high speed recommended, avoid excessive shear which may cause material degradation. ‑Runner & gate: all conventional gate types are applicable; gate thickness shall not be less than half of product wall‑thickness.
Disclaimer: All above data is for reference only.