POM Polyplastics DURACON M270‑44
POM Polyplastics DURACON® M270‑44 (Japan Polyplastics)
POM Polyplastics M270‑44 is a high‑flow engineering plastic with stable dimensional performance, good wear resistance and excellent mechanical properties. It is especially suitable for production scenarios requiring fast molding cycles and good filling performance, such as thin‑wall products with complex structures.
Main Applications
Automotive industry: fuel‑tank caps, fuel‑pump components, seat‑belt parts, interior functional components and other automotive parts. Electrical & electronic: structural parts and transmission components for OA equipment such as printers and copiers; parts for DVD/Blu‑ray players; gears and bearings for household appliances such as washing‑machines, refrigerators and electric shavers. Consumer & industrial goods: residential‑sector articles including zippers, buttons, window‑frame and shutter components; toys and sports‑equipment parts. Precision‑machinery parts: ideal for manufacturing various mechanical structural components with high‑precision, high‑wear‑resistance and low‑friction requirements, such as gears, screws, bearings, cams and guide rails.
Physical‑Mechanical‑Thermal‑Electrical‑Tribological Properties
| Property Category | Item | Test Standard | Value | Unit |
|---|---|---|---|---|
| Physical Properties | Density | ISO 1183 | 1.41 | g/cm³ |
| Water absorption (23℃, 24h) | ISO 62 | 0.5 | % | |
| MFR (190℃ / 2.16 kg) | ISO 1133 | 27 | g/10 min | |
| MVR (190℃ / 2.16 kg) | ISO 1133 | 23 | cm³/10 min | |
| Mechanical Properties | Tensile strength | ISO 527‑1,2 | 63 | MPa |
| Elongation at break | ISO 527‑1,2 | 30 | % | |
| Tensile modulus | ISO 527‑1,2 | 2800 | MPa | |
| Flexural strength | ISO 178 | 88 | MPa | |
| Flexural modulus | ISO 178 | 2550 | MPa | |
| Charpy notched impact strength (23℃) | ISO 179/1eA | 5.3 | kJ/m² | |
| Rockwell hardness (M scale) | ISO 2039‑2 | 80 | — | |
| Thermal Properties | Heat deflection temperature (1.8 MPa) | ISO 75‑1,2 | 100 | °C |
| Coefficient of linear thermal expansion (flow / cross‑flow, 23‑55°C) | ISO 11359‑2 | 11 | ×10⁻⁵/°C | |
| Electrical Properties | Volume resistivity | IEC 60093 | 1 × 10¹⁴ | Ω·cm |
| Surface resistivity | IEC 60093 | 1 × 10¹⁶ | Ω | |
| Dielectric strength (3 mm) | IEC 60243‑1 | 19 | kV/mm | |
| Flammability | UL94 rating | UL 94 | HB | — |
| Molding shrinkage (flow / cross‑flow direction) | ISO 294‑4 | 1.9 | % |
Processing Parameters
| Process Stage | Parameter | Recommended Value / Range | Unit | Remarks |
|---|---|---|---|---|
| Pre‑drying | Drying temperature | 80‑90 | °C | Drying is recommended. Preheating improves dimensional stability even though drying may be omitted in some cases. |
| Drying time | 3‑4 | hr | ||
| Residual moisture content | < 0.1 | % | ||
| Barrel temperature | Rear‑zone temperature | 180‑200 | °C | POM has a narrow processing window. Temperatures above 220 °C are strictly prohibited; otherwise formaldehyde gas will be generated through thermal decomposition. |
| Middle‑zone temperature | 180‑195 | °C | ||
| Front‑zone temperature | 185‑210 | °C | ||
| Nozzle temperature | 180‑210 | °C | Slightly lower than front‑zone temperature. | |
| Melt temperature | 190‑210 | °C | ||
| Mold temperature | 60‑80 (can be increased up to 75‑120) | °C | Higher mold‑temperature promotes crystallization integrity and improves dimensional stability and surface gloss. | |
| Injection parameters | Injection pressure | 49‑98 (or 40‑130) | MPa | Higher value for thin‑wall parts; lower value for thick‑wall parts. |
| Hold‑up pressure | 50‑150 | MPa | Relatively high hold‑up pressure (comparable to injection pressure) is required to reduce pressure drop. | |
| Back pressure | 0.5‑3.0 | MPa | Maintain low back‑pressure. | |
| Injection speed | Medium‑to‑high | — | Medium speed is recommended. | |
| Screw speed | 100‑150 | rpm | Excessively high rotational speed is not advised. | |
| Post‑treatment | — | — | — | Generally unnecessary. Conditioning or annealing treatment can be applied for high‑precision parts to release internal‑stress. |
| Barrel residence time | <20 | min | Avoid long‑term high‑temperature retention. | |
| Shutdown procedure | Short‑term stop | Cool barrel below 150 | °C | Long‑term shutdown purge barrel with PE / PP. |